Re: GRC AC: SP12: Config Parameters
Ronnie, You can find the full configuration parameter guide on the service marketplace. Hopefully the link below will work for you. The version available there will be based on the latest SP (i.e....
View ArticleRe: No Alerts RWB
Hi Vicky, Try using the container variable "SXMS_TO_ADAPTER_ERRLINES". Regards,Pranay
View ArticleRe: Adding new user to Approval procedure
Hi Richard, Please refer SAP note 1300817 - No Ratio has been defined for solution for solution. Where to define the ratio: Thanks & Regards,Nagarajan
View ArticleRe: Change from WebDynpro to SAPUI5
Hi Martin, the best advice I can give you is to try it and see. Take a simple (but not too simple) WDJ app and try porting it to SAPUI5. Be warned there is a fundamental paradigm change known as...
View ArticleRe: VAT number in Ship to address
Hi, Please check with SAP note: 1863608 - VAT id on Marketing Document not correctly updated when VAT number blank for delivery address Thanks & Regards,Nagarajan
View ArticleRe: unable to see project sales orders through CN55N
Another thing to check is to make sure that the Sales Order Line Item is account assigned to the WBS element and not just the Sales Order Header. The account assignment in the SO header is not really...
View ArticleRe: One to many relationship between Std network & Std WBS
A standard network header or activity can only be assigned to one standard WBS. For what you describe you could not assign the standard network to any standard WBS. Then when you build the project...
View ArticleRe: How to Print Several PO in 1 Form with Smartforms
Hi Danny, yes, I do like you said, can you tell me about this ?
View ArticleRe: WEBi update after changing BW hierarchy
Hi Shai, I'm facing same issue. Have you find a way to automate it? Or at least, is there any SAP note / documentation about this? Customer is asking for this. Thanks,Liliana
View ArticleRe: Dashboard Designer runs too slow
Mutu, there are few thing you could do to troubleshoot your Dashboard. If nothing of the above works, then you have to do some homework to improve the performance. 1.- For each one of the WSDL that...
View ArticleWDA HCMPF application unable to read selected pernr
Hi All, I have configured the Launch pad to start the WDA HCMPF applications. We are using MSS Add On Team app to launch HCMPF apps. The app is unable to read the selected pernr. In the Parameters I am...
View ArticleRe: Release strategy reset automatically while doing mass change in po
Yes it’s true the fields that were mentioned should not affect the release strategy.But actually it dose effect the release strategy in First scenario.Example if I have 1000 old purchase orders that I...
View ArticleRe: How to map two columns to one dimension with conversion file
Hi Daniel, Please share your transformation file and conversion file. Regards,Kalyan.
View ArticleRe: issue with a buffered program
Hi, Its just a TEMP version you can just revert in version mgmt. also I think no issues if its there even. Cheers,arindam
View ArticleRe: Gateway Projects not appearing in search list
Abhishek, I believe only one user can work on a project at a time.When you create a project you give "Person Responsible", defaulted to current user. Check that, try changing it. Experts correct me, if...
View ArticleRe: dev_disp: *** ERROR => NiPConnect2: SiPeekPendConn failed for hdl
Hi Americo,--- lgtst -H sapgrptcd -S 3901 --- using trcfile: dev_lg[Thr 4744][Thr 4744] *****************************************************************************[Thr 4744] *[Thr 4744] * ERROR...
View ArticleRe: Same Table in 3 Pages of Adobe.
Hi Rakesh, Yes, I would like to do it using JavaScript, but I am pretty new to JavaScript.Are you handy with JavaScript ? What I was planning is,to write the java script code, which could tell the...
View ArticleRe: dev_disp: *** ERROR => NiPConnect2: SiPeekPendConn failed for hdl
Hi Roman, FYI. I will read system copy guide of SWPM 1.0. again later.-- 1st node ---------------------------------------------------Windows IP Configuration Host Name . . . . . . . . . . . . :...
View ArticleRe: dev_disp: *** ERROR => NiPConnect2: SiPeekPendConn failed for hdl
Hi Americo, Instance number 00 is DI. Instance number 01 is ASCS. S:\usr\sap\TCD\SYS\profile>sapcontrol -nr 00 -function ParameterValue rdisp/mshost 24.08.2013 09:12:56ParameterValueFAIL: HTTP...
View Article